Specifications:
GE LM6000 44MW Power Plant LM6000 Equipment Package Description LM6000 engine is coupled with a generator and is Main information Description of the LM6000 : 7LM6000PDNGD03 S/N192.148 Year Last Availability rate Generator Reductor Technical data This section lists the general descriptions , capacities, and Engine Ignition Exciter Generator Turbine Hydraulic Starter System Ventilation and Combustion Air System Gas Fuel System Generator Lube Oil System Turbine Lube Oil System Turbine Hydraulic System Fire Suppression and Gas Detection System : Turbine Water Wash System Control System Price & terms : Please enquire using the email form below. If you cannot find the vessel, crane, rig or equipment that you need, We can arrange delivery of equipment and towage of rigs and vessels where needed. The details mentioned above are believed to be accurate but are not guaranteed. ------------------------------------------------------------------------------------------------------------
44MW Power Plant for Sale
Description :
equipped with a heat recovery boiler. The power plant
works perfectly until it was turn off in March 2013.
Commissioning date : November 2001
Package Hours: 45 388 hours
Engine running hours : 45 388 hours
2009/2010 99,6%
2010/2011 95,5%
2011/2012 100%
2012/2013 98,6%
— Running hours : 45 388 hours
— Manufacturer: BRUSH (FKI Rotationg Machines)
— Output 53500Kva
— R/min 3000
— Volts 11500 Amps=3188
— Turbo generator type : BDAX7-290ERJT 50Hz
— Machine N° 904118.010
— N° de series 904118
— CustN° 27674829
— Part numb: 31767200
— running hours : 45 388 hours
— Manufacturer: FLENDER GRAFFENSTADEN
— Ref : STEWART/STEVENSEN 655211
— Type : TX61/1CV N°5713
— Power : 52200KW
— Speed : 3627/3000
— Weight : 13500kg
capabilities for the gas turbine-generator set including associated
support systems.
— Manufacturer : General Electric
— Model N° 7LM600-PD
— Type : Gas turbine
— Engine Weight : 13 270 Ib
— Operating Speed :
• LP Rotor : 3600 rpm
• HP Rotor : 10 200 rpm
— Start System : Hydraulic
— Manufacturer : Unison
— Manufacturer : FKI Rotationg Machines
— Type : Air-cooled
— Manufacturer : Sunstrand
— Hydraulic Reservoir capacity : 40gal
— Charge pump : 56gpm @5200 psig
— Starter Motor : ABB motors
— (200-hp, 400-VAC, 3Ф, 50-Hz)
— Hydraulic Fluid: Recommendations in manual.
— Air Filtration System : ALTAIR
— Turbine Ventilation Fans : TCF Aerovent
(2 fans – 1 operates, 1 is on standby, 60,000 scfm each)
— Generator Ventilation Fans : TCF Aerovent
(2 fans – 1 operates, 1 is on standby, 39,000 acfm each)
— Silencers :
• Air inlet Silencer Manufacturer : ALTAIR
• Turbine Room Vent Fans Silencer Manufacturer : TCF AEROVENT
• Variable Bypass Valve Silencer Manufacturer : VAW
• Generator Exhaust Silencer Manufacturer : VAW
— Input required : Natural Gaz, 400MMBtu/hr, max
— Supply pressure : 655 – 695 psig
— Supply Temperature : 250°F, max
— Fuel Filter 3µ, absolute
Gas Fuel Flow – Control Valve : WOODWARD
— Reservoir Capacity : 3000 gal
— Generator Lube Oil Supply Filters :
• Rating : 6µ, absolute
• Manufacturer : PALL
— Generator / Gearbox Lube Oil Heat Exchangers
• Cooling : Fin /Fan
• Manufacturer : Thermal Mechanical
— AC Lube Oil Pump : LEISTRITZ
— Reservoir Capacity : 150 gal
— Turbine Lube Oil Supply Filters :
• Rating : 6µ, absolute
• Manufacturer : PALL
— Turbine Lube Oil Heat Exchangers
• Cooling : Fin /Fan
• Manufacturer : Thermal Mechanical
— Prime Mover : Direct connection to turbine accessory gearbox
— Internal Relief Valve Setting on Hydraulic Supply
Pump : 800 psig
— Filters Rating : 3µ, absolute
— Manufacturer : WILSON FIRE EQUIPMENT & SERVICE
COMPANY, Inc
— Fire Suppressant : CO2 gas
— Thermal Spot Detectors : 225°F and 450°F plus rate of rise
— Optical Flame Detectors : Duel-frequency infrared 90° view
cone
— Combustible Gas Detector : Methane
— Water Supply Pressure : 15 – 65 psig
— Tank Capacity : 100 gal
— Instrument Air Pressure : 80- 120 psig filtered to 3µ,
absolute
— Detergent: Added in solution with water wash in proportion, as
specified by manufacturer of detergent
— Antifreeze : Isopropyl Alcohol, Methyl Ethyl Ketone (MEK) or
Acetone, detergent manufacturer must specify which of these is
compatible with detergent
— Fuel Control /Sequencer : WOODWARD
— Automatic Voltage Regulator (AVR) : FKI ROTATING
MACHINES
— Vibration Monitor : BENTLY NEVADA
please send us an email to mail@worldoils.com stating your
requirements and we shall find it for you.
Search words (for official use only) -
GE LM6000 44MW Power Plant
44MW Power Plant for Sale
General Electric LM6000 power plant
44 Megawatts Power plant for Sale
General Electric 44MW Power Plant
-----------------------------------------------------------------------------------------------------------
Select equipment to compare...